ETS is introducing Wireless data communication from the well head to the data cabin.
The QM 200 measures pressure and temperature and includes Replaceable 200°C memory module (part no. 101864).
QUARTZ "DMB", QM 200, 1.25" OD, INCONEL 718, 200°C |
||||||
Pressure |
Kit includes a calibrated module, memory module, battery barrel, bullnose, standard Viton o-rings, and PEEK back-up. |
|||||
150°C |
177°C |
200°C |
||||
Kit |
Calibrated |
Kit |
Calibrated |
Kit |
Calibrated |
|
10 |
101040 |
101039 |
- |
- |
- |
- |
16 |
101473 |
101467 |
105057 |
101467 |
101862 |
101860 |
20 |
- |
- |
101475 |
101469 |
101863 |
101861 |
25* |
- |
- |
- |
104305 |
103263 |
103975 |
* Do not exceed maximum external pressure specifications of 20 ksi. |
Battery specifications:
Lithium Battery Pack Description (sorted on Temperature) |
|||||||
Qty |
Type |
Voltage |
CAP (Ah) |
Temp (°C) |
OAL (inch) |
Connector |
Part No. |
1 |
2 C (PARALLEL) For short battery |
3.9 |
12.4 |
150 |
6.6875 |
4 PIN LEMO |
102122 |
1 |
2 CC (PARALLEL) |
3.9 |
26 |
165 |
10.8 |
4 PIN LEMO |
101059 |
1 |
2 CC (PARALLEL) |
3.6 |
24.2 |
180 |
10.8 |
4 PIN LEMO |
104793 |
1 |
4 C (PARALLEL) |
3.6 |
18 |
200 |
10.8 |
4 PIN LEMO |
101925 |
General specifications are given below in the table
General specifications |
|
Pressure |
|
Maximum external pressure |
20 ksi |
Sensor type |
Quartz |
Accuracy |
± 0.02% full scale |
Long term stability |
0.015% full scale |
Drift |
0.02% full scale per year |
Resolution |
< 0.008 % psi/sec. |
Temperature |
|
Maximum temperature |
200ºC |
Accuracy |
± 0.15ºC |
Repeatability |
< 0.01ºC |
Resolution |
< 0.01ºC per second |
Power |
|
Battery type |
2 CC Lithium |
Operating voltage |
3.2 to 3.6 V |
Memory |
|
Sampling interval |
One second to one hour |
Capacity |
1,000,000 samples in sequential mode or 500,000 in redundant memory mode |
Record contents |
Time, pressure, temperature |
Downhole Gauges :
Eastern Testing Services has a full range of gauges for any pressure and any temperature. We carry upto 20K Psi gauges.. We have gauges capable of downhole temperatures as high as 200 °C (392 °F). We use quartz gauges only, the best answer when it comes to accuracy and resolution. In addition to the usual methods of landing gauges, we can mount slim hole gauges in a gauge carrier and run them in the well on the tubing with great success. We can run gauges under a plug for Frac tests. And of course, we do the more conventional static gradients and build-up tests. All of our trucks are capable of e-mailing data from location for rush jobs, as well as the ability to generate field reports in electronic or hard copy right in the truck. Eastern Testing Services knows how important your data is. That's why we only use the most reliable downhole gauges. We use Canada Tech gauges. We have a goal of sending out test results within 24 hours of completion of the test. Within that time, we make every effort to send you a copy of the report in pdf format, as well as in ascii file formats. The printed copy with files on disc usually follows the next day. Our reporting department is located in Islamabad, Pakistan so we can get you your results ASAP.