WIRELESS PRESSURE GAUGE

Description

The wireless pressure gauge is a key component of the AKS FieldPORT™ wireless monitoring systems. There are a wide variety of pressure ranges available with more on the way. Each gauge is fully characterized over temperature providing outstanding performance at a reasonable price. Each gauge is self-powered and contains a pressure sensor, signal conditioning circuitry and an RF transceiver operating in the 902 MHz to 928 MHz ISM license-free band. Remote mount sensors and high-gain antennas are available as options for the gauge pressure units.

Data from the sensor are transmitted to a Base Radio Logger for centralized monitoring and data acquisition. You may specify updates between once per second and once per minute based on how frequently the process is monitored and how often the data is transmitted.

Gauge Pressure Models

Model

Range

AKS-GP-15

15 PSIG

AKS-GP-30

30 PSIG

AKS-GP-I00

100 PSIG

AKS-GP-250

250 PSIG

AKS-GP-1000

1,000 PSIG

AKS-GP-5000

5,000 PSIG

AKS-GP-l0000 Available
July, 2007)

10,000 PSIG

Specifications

Integrated Application Packages

  • Production Well Test Package
  • Well Site Monitoring Package
  • Artificial Lift Optimization Package

Accuracy

  • ±0.1% of sensor URL including combined effects of linearity, hysteresis, repeatability and temperature.

Stability

  • Combined zero and span stability: less than :.to.1% of sensor URL per year at 70°F.

Operating Ambient Environment

  • Operating: -40°F to + 185°F (-40°C to +85°C)
  • Process: -40°F to + 250°F (-40°C to 121°C) process temperature, steady state sensor
  • Humidity limits: 0 to 95%, non-condensing

Power Characteristics

  • Self-contained power
  • 'C' size 3.6 V lithium battery
  • Up to five year battery life (depends on sample rate and RF update rate (field replaceable)

RF Characteristics

  • 902 MHz - 928 MHz Frequency Hopping Spread Spectrum (FHSS) FCC certified ISM license-free band
  • Up to 3000' range from Base Radio with clear line of sight; 500' to 1000' typical range with obstructions

Self-Diagnostics

  • Low battery alarm-indicates the need to replace the battery (approximately one month warning)
  • Extensive self-diagnostics

Local Configuration

  • Integrated LCD display with membrane switch buttons
  • Configure sampling and RF parameters locally using membrane switches.
  • Enhanced configuration includes 22 point fit table

Materials of Construction

  • Type 316 stainless steel base and diaphragm



 