Description
The wireless level gauge is a key component of the AKS FieldPORT™ wireless monitoring systems. The temperature gauge comes in both RTD and thermocouple versions. The selection of sensor type depends on the AKS Technologies package that is selected and the specific measurement required.
Each gauge is self-powered and contains a temperature sensor, signal conditioning circuitry and ar RF transceiver operating In the 902 MHz to 928 Mhz ISM license-free band. Remote mount sensors and high-gain antennas are available as options for the gauge pressure units. Sensor lengths may be selected aid options for weld or spring-Ioad are available.
Data from the sensor are transmitted to the Base Rad for centralized monitoring and data acquisition. You may specify updates between once per second and once per minute based on how frequently the process is monitored and how often the data is transmitted.
Temperature Gauge Models
Model
|
Range |
A.KS-RT-bN-xxx |
-328 to +392°F ( LO) |
AKS-TC-xxx |
B,C,R,J,K,L,N,R,S,T,U |
Specifications
Integrated Application Packages
- Production Well Test Package
- Well Site Monitoring Package
- Artificial Lift Optimization Package
Accuracy
- ±0.1% of full-scale reading plus 1.8°F (1°C) for thermo::ouple cold-junction effect at reference conditions.
- RTD: ±0.002% of reading per °c for ambient temperature effect
- Thermocouple: ±0.0l %of reading per °C for ambient temperature effect
- RED and thermocouple linearization to ±0.05°C
- Custom linearization with 22-point curve
Stability
- Stability deviation per year is less than 0.025%
Operating Ambient Environment
- Operating: -40°F to + 185°F (-40°C to +85°C)
- Humidity limits: 0 to 95% non-condensing
Power Characteristics
- Self-contained power
- 'C' size 3.6 V lithium battery
- Up to five year battery life (depends on sample rate and RF update rate (field replaceable)
RF Characteristics
- 902 MHz - 928 MHz Frequency Hopping Spread Spectrum (FHSS) FCC certified ISM license-free band
- Up to 3000' range from Base Radio with clear line of sight; 500' to 1000' typical range with obstructions
Self-Diagnostics
- Low battery alarm-indicates the need to replace the battery (approximately one month warning)
- Extensive self-diagnostics
Local Configuration
- Integrated LCD display with membrane switch buttons
- Configure sampling and RF parameters locally using membrane switches